How should the hydraulic system air cooler be used to increase the life?

June 03, 2020
In order to improve the service life of the hydraulic system air cooler, it is necessary to strictly follow the precautions listed in the Dalan Hydraulics. 
In order to improve the service life of the hydraulic system air cooler, it is necessary to strictly follow the precautions listed in the Dalan Hydraulics. 

The air cooler use precautions are as follows: 

1, the highest use pressure 

1AF series: 15bar; 

2AH series: 20bar; 

3AJ series: 20bar; 

4FR series: 20bar. 

2. Operating temperature: The maximum operating temperature is 140 °C. 

3. Applicable media 

1 mineral oil (anti-wear hydraulic oil); 

2 anti-combustion hydraulic oil (high water base, oil water emulsion, synthetic liquid); 

3 liquids that do not corrosively react with aluminum. 

4, piping considerations: 

1 The pipe diameter should match the size of the inlet and outlet ports and cannot be changed or reduced; 

2 Use high pressure hoses and direct joints as much as possible to reduce oil return resistance; 

3 Use hydraulic oil as much as possible. The faster the oil return, the smoother the heat transfer, the better the heat dissipation effect; 

4 When using the oil return cooling method, a bypass unloading circuit (check valve) must be installed in parallel with the cooler. The opening pressure of the back pressure valve is less than 0.5Mpa to prevent excessive pulse pressure from being damaged when the system starts. . 

5 The position of the air cooler should avoid vibration and impact, and the air intake and exhaust are free and smooth, and the installation is firm. 

6 It is not recommended to install a cooler at the oil outlet. 

5, installation precautions 

1 The cooler must be placed in a well ventilated place, and dust and debris should be cleaned regularly. The front and rear exhaust vents must have a space above the fan blade radius for good air circulation and heat exchange. 

2 In order to protect the cooler from being broken, when the cooler device is installed in the return oil circuit, a bypass unloading circuit must be installed, connected in parallel with the cooler, and when the pressure relief encounters the convex wave, the unloading can be preferentially opened. 

3 For proper installation, it is recommended to use a hose, correctly install a bypass unloading circuit, or use an independent circulation cooling method. 

4 Clean the air side, use compressed air or hot water, remove it along the direction of the aluminum sheet. Please pay attention to the power failure during cleaning, and protect the fan coil from water. 
ကြှနျုပျတို့ကိုဆကျသှယျရနျ

Author:

Ms. Judy Tang

Phone/WhatsApp:

8615768337174

လူကြိုက်များတဲ့ထုတ်ကုန်များ
You may also like
Related Categories

ဒီကုန်ပစ္စည်းပေးသွင်းအီးမေးလ်

ဘာသာရပ်:
အီးမေးလ်ပို့ရန်:
မက်ဆေ့ခ်ျကို:

Your message must be betwwen 20-8000 characters

ငါတို့သည်သင်တို့ကိုချက်ချင်းဆက်သွယ်ပါလိမ့်မယ်

ပိုမိုမြန်ဆန်စွာဆက်သွယ်နိုင်အောင်ပိုမိုသောအချက်အလက်များကိုဖြည့်ပါ

Privacy ထုတ်ပြန်ချက် - သင်၏ privacy သည်ကျွန်ုပ်တို့အတွက်အလွန်အရေးကြီးသည်။ သင်၏ကုမ္ပဏီ၏ကိုယ်ရေးကိုယ်တာအချက်အလက်များကိုသင်၏ရှင်းလင်းပြတ်သားသောခွင့်ပြုချက်များနှင့်အတူမည်သည့်ထုတ်ဖော်ပြောဆိုမှုကိုမထုတ်ဖော်ရန်ကတိပေးသည်။

ပေးပို့